Non-Generate Load Input

Discussion in 'Chuyên ngành Offshore' started by hoangtu, Mar 7, 2023.

  1. hoangtu

    hoangtu Moderators Staff Member

    Joined:
    May 20, 2012
    Messages:
    675
    Likes Received:
    46
    Trophy Points:
    28
    Trong khi input load vao sac, cac thong tin duoi day co the assume de dung

    1. Handrail: 0.3 kN/m
    2. Grating 52 kg/m2
    3. Secondary weight
    4. Anode weight alloy weight of 500kg
    IPE 220 unit weight = 26.2 kg/m
    Total run = 56.4 m @ 1000mm intervals = 56.4m*40 Nos * 26.2 = 59.107 MT
    Cantilever 5.34m * 11 Nos * 26.2 = 1.54 MT
    TBD if assumed wt to be reduced?
    .
    ......
     